You now need to check, in the application status word, that the conditions for starting the cross cutter in mark-
controlled operation have been met (Short Setup Control/Status Interface Status Interface):

Click code C4150/000 to open the application status word.

The following bits have to be set to start mark-controlled operation:

Bit 12 Cutting profile calculation OK
Bit 13

Reject profile calculation OK

Bit 14

Test profile calculation OK

Bit 15

Start/stop profile calculation OK

Bit 17

Home position detected

Bit 31

Profile calculation complete

The following bits must not be set to start mark-controlled operation:

Bit 0 Error status
Bit 1

Following error warning

Bit 2

Following error disconnection

Bit 18 Homing error


Check the following code:

C3505/000

The system must be in standby (10).

Step 5