Variable names, Cross cutter, Features of the "cross cutter" prepared solution – Lenze EVS93xx CrossCutter User Manual

Page 58

Advertising
background image

Cross Cutter

Features of the "Cross Cutter" prepared solution



Prepared Solution Servo PLC / ECSxA 1.1 EN

2-44

)

g_bManualJogNeg

g_bManualJogPos

Ramp Time: C3622/1..3

Speed: C3623/1..2

ManualJog

g_bGlobalError

In

pu

ts

Pa

ra

m

et

er

)

g_bManualJogNeg

g_bManualJogPos

Ramp Time: C3622/1..3

Speed: C3623/1..2

ManualJog

g_bGlobalError

In

pu

ts

Pa

ra

m

et

er

Figure 9: Control signals in ManualJog

Variable

names

Global variables

(Variable type: VAR_GLOBAL)

Name Data

type

Value/Meaning

Manual jog in negative direction (CCW)

This value is written in code C4135/000 bit 4.
This value is displayed in code C4136/000 bit 4.

TRUE

Manual jog in negative direction

g_bManualJogNeg BOOL

FALSE Stop

Manual jog in positive direction (CW)

This value is written in code C4135/000 bit 3.
This value is displayed in code C4136/000 bit 3.

TRUE

Manual jog in positive direction

g_bManualJogPos BOOL

FALSE Stop

Possible settings:

Code

Default

Selection

Comment

C3622

/001

5.000 0.000...

{0.0001[s]}

...129.99

Deceleration ramp for immediate stop

Assuming 4000 rpm

C3622

/003

5.000 0.000...

{0.0001[s]}

...129.99

Acceleration and deceleration ramp for manual jog

Assuming 4000 rpm

C3623

/001

200 0

...

{1 rpm}

...15000

Speed for manual jog in positive direction (CW)

C3623

/002

200 0

...

{1 rpm}

...15000

Speed for manual jog in negative direction (CCW)

Application control word bit 3: Manual jog in positive direction
(CW)

TRUE

Manual jog in positive direction

C4135

/000

Bit 3

0

0 {1} 1

FALSE Stop
Application control word bit 4: Manual jog in negative direction
(CCW)

TRUE

Manual jog in negative direction

C4135

/000

Bit 4

0

0 {1} 1

FALSE Stop

Advertising