Cross Cutter

Features of the "Cross Cutter" prepared solution



Prepared Solution Servo PLC / ECSxA 1.1 EN

2-77

002

/

3673

4000

001

/

3673

4000

C

rpm

t

T

on

decelerati

C

rpm

t

T

on

accelerati

if

if

ir

ir

=

=

Following calculation, you will need to enter the values T

ir

and T

if

in the specially designated

code (C3672/002 = acceleration time T

ir

; C3672/003 = deceleration time T

if

respectively).

Example: The forward and return speeds are to be 200 rpm. Each speed value needs to be
reached within 1 sec. This results in the following values for T

ir

and T

if

when the formula below

is applied:

sec

20

200

4000

sec

1

002

/

3673

4000

sec

20

200

4000

sec

1

001

/

3673

4000

=

=

=

=

=

=

rpm

rpm

C

rpm

t

T

rpm

rpm

C

rpm

t

T

if

if

ir

ir

Advertising