Installing and starting up the "CrossCutter" prepared solution



Prepared Solution Servo PLC / ECSxA 1.1 EN

3-117

3.4.3

Downloading the CrossCutter_SPLC_Vxxxx.bin program and
CrossCutter_ECS_Vxxxx.bin

Requirements:

The servo controller has been set up and wired in accordance with the wiring plan in Chapter 3.3.1 and
as per the product documentation.

The axis has been inhibited via terminal 28 if you are using 9300 Servo PLC or via terminal SI1 if you
are using the ECS.

Control voltage is being supplied to the axis via terminals 59 (+24 V DC) and 39 (GND).

Use of keypad XT EMZ9371BC to make and modify code parameter settings.

The prepared solution cross cutter and the required Lenze software tools have been installed on your
PC/laptop.

The EMF2177IB/EMF2173IB system bus adapter has been successfully installed.






Use the keypad XT EMZ9371IB to set the following codes on the cross cutter's servo controller in the
sequence indicated:

C2108/000 2 = Stop active PLC program
C0002/000 0 = Apply default setting
C0350/000 Node address of servo axis (each node address can only be used once on the system bus)
C0352/000
C0003/000

1 = Cross-cutter servo controller is bus master on system bus
1 = Saving of system bus settings to non-volatile memory




Disconnect the power supply entirely from the cross-cutter servo controller and wait for the red and green
status LEDs on the servo controller to go out, or for at least 20 s.

Step 2

Start

Step 1

Status LEDs