Cross Cutter

Features of the "Cross Cutter" prepared solution



Prepared Solution Servo PLC / ECSxA 1.1 EN

2-27

Outputs

Global variables

(Variable type: VAR_GLOBAL)

Name Data

type

Value/Meaning

g_nNumberOfKnives

INT

Number of knives mounted on the knife drum.

This value is displayed in code C3690/000.

Status signal: Cutting length induces start/stop operation of cross cutter.
This value is displayed in code C3700/000.
TRUE

The selected cutting length exceeds the
limit cutting length for start/stop
operation => The pause will be extended
accordingly in the asynchronous motion
phase.

g_bStartStopOperationCuttingProfile

BOOL

FALSE

The selected cutting length undershoots
the limit cutting length for start/stop
operation. (See Chapter 2.2.2
Synchronous cross cutter.)

Status signal: Reject length induces start/stop operation of cross cutter.
This value is displayed in code C3701/000.
TRUE

The selected reject length exceeds the
limit cutting length for start/stop
operation => The pause will be extended
accordingly in the asynchronous motion
phase.

g_bStartStopOperationRejectProfile BOOL

FALSE

The selected reject length undershoots
the limit cutting length for start/stop
operation. (See Chapter 2.2.2
Synchronous cross cutter.)

Status signal: Test length induces start/stop operation of cross cutter.
This value is displayed in code C3702/000.
TRUE

The selected test length exceeds the
limit cutting length for start/stop
operation => The pause will be extended
accordingly in the asynchronous motion
phase.

g_bStartStopOperationTestProfile BOOL

FALSE

The selected test length undershoots the
limit cutting length for start/stop
operation. (See Chapter 2.2.2
Synchronous cross cutter.)

Status signal: Start/stop length induces start/stop operation of cross cutter.
This value is displayed in code C3703/000.
TRUE

The selected start/stop length exceeds
the limit cutting length for start/stop
operation => The pause will be extended

accordingly in the asynchronous motion
phase.

g_bStartStopOperationStartStopProfile BOOL

FALSE

The selected start/stop length
undershoots the limit cutting length for
start/stop operation. (See Chapter 2.2.2

Synchronous cross cutter.)

Advertising