Cross cutter, Appendix – Lenze EVS93xx CrossCutter User Manual

Page 275

Advertising
background image

Cross Cutter

Appendix



Prepared Solution Servo PLC / ECSxA 1.1 EN

6-107

The following structure will be used to provide a practical illustration of the application of the
Tp_Register function block:

Upstream of a printing unit, print marks are detected via a sensor mounted ∆l = 1230 mm
upstream of the printing unit. The web is moving forwards at approx. 60 m/min. The feed motion
is detected via an incremental encoder driven via a belt ratio i

master

= 5 : 2 by one of the feed

rolls (diameter Ø

master

= 100 mm).

The required shifting of the print-mark signals by the offset distance of ∆l = 1230 mm can be
achieved using the Tp_Register function block in the following connection:

The incremental value for the offset distance (input signal dnOffset_p) is calculated using the
following formula:

...

269

,

641468

]

/

[

100

]

[

1230

2

5

]

/

.

[

65536

]

/

.

[

65536

_

=

=

=

Δ

=

rev

mm

mm

rev

incr

m

l

i

rev

incr

p

dnOffset

Master

Master

π

∆l = 1230 mm

i

master

= 5 : 2

m

master

= π

.

100 mm