Cross cutter, Features of the "cross cutter" prepared solution – Lenze EVS93xx CrossCutter User Manual

Page 69

Advertising
background image

Cross Cutter

Features of the "Cross Cutter" prepared solution



Prepared Solution Servo PLC / ECSxA 1.1 EN

2-55

Possible settings:

Code

Default

Selection

Comment

Application status word bit 16: Homing activated.
TRUE

Homing active.

C4150/

000

Bit 16

-

- - -

FALSE

Homing not active.

Application status word bit 17: Home position detected.
TRUE

Homing complete, home position detected.

C4150/

000

Bit 17

-

- - -

FALSE

Home position not detected (an encoder error
may have occurred).

Application status word bit 18: "Homing error" status signal.
TRUE

An error occurred when setting the home
position.
See g_nHomingErrorNo for more detailed
information about the error.

C4150/

000

Bit 18

-

- - -

FALSE

No errors occurred when setting the home

position.

Note!
Tip for assigning the PLC's digital input to the homing switch:
In the prepared solution, digital input 3 is designated as the homing switch.

The signals are wired in the CrossCutterInterfaces PRG (network 3).

Instead of the touch-probe signal via digital input (I4 using Servo PLC and I2 using ECS),
the zero pulse signal from the feedback system can also be used as the signal to determine
the home position.

Advertising