6.1.18 VarVertShaftExtPosition

Inputs

Global variables

(Variable type: VAR_GLOBAL)

Name Data

type

Value/Meaning
Enable external master signal.
TRUE

X axis defined externally.

g_bVertShaftExtEnable BOOL

FALSE

X axis generated by virtual master.

Positioning to external master angle
TRUE

Positioning to external master angle.

g_bPosToVertShaftExt BOOL

FALSE

Direct switch to external master angle.

6.1.19 VarVertShaftExtVelocity

Inputs

Global variables

(Variable type: VAR_GLOBAL)

Name Data

type

Value/Meaning
Selection of external master signal
TRUE Digital

frequency

via digital frequency

input DFIN.

g_bTypeOfVertShaftExt BOOL

FALSE

Master angle via system bus (CAN).

Selection of operating mode

0 Continuous

operation

The external digital frequency entry is
integrated continuously.

g_byVertShaftExtVelMode BYTE

1 Start/stop

operation

The external digital frequency entry is
only integrated when a corresponding
start/stop signal is pending at
g_bStartStopVertShaftExtVel.

Start/stop signal for "Start/stop operation"
TRUE Start

integration.

Integration will continue at least until the
next zero crossing.

g_bStartStopVertShaftExtVel BOOL

FALSE No

integration/abort previously activated

integration on the next zero crossing.

g_nVertShaftExt_v INT

Entry indicating the external digital frequency/speed in [incr./ms]
Invert external digital frequency entry.

g_bVertShaftExtVelCwCcw BOOL

TRUE

g_nVertShaftExt_v inverted internally.