Cross Cutter

Features of the "Cross Cutter" prepared solution



Prepared Solution Servo PLC / ECSxA 1.1 EN

2-71

Possible settings:

Code

Default

Selection

Comment

C3669/

000

60.0000 0.0000...

{0.0001

m_units}

... 214000.0000

Size of mark window

C3670/

000

1

0 ...

{1}

... 65535

Number of cycles permitted without a mark signal appearing in
the mark window. A warning signal is generated if this number is
exceeded.

Application status word bit 26: This status signal indicates that the
maximum number of cycles completed without a mark signal
appearing in the mark window has been exceeded.
TRUE

The maximum number of cycles without a mark
signal appearing in the mark window has been
reached.

C4150/

000

Bit 26

-

- - -

FALSE

The maximum number of cycles without a mark
signal appearing in the mark window has not been
reached.

The warning signals listed in the table below may occur during monitoring of the mark window.
Each warning signal will remain pending until the next print-mark signal appears in the mark
window. Warning signals can also be displayed via bit 26 of the application status word
(C4150/000).

Each warning signal is generated in the specified network of the UserErrors block (POU).

Warning signals

Number

Text

Global variable

Network in
UserErrors
POU

507 MaxNumberOfTPOutOfWin

g_bMaxNumberOfTPOutOfWindowIncreased 8

Note!
Digital input 5 on the Servo PLC or I1 on the ECS is permanently assigned to the print-
mark-sensor signal. The user needs to assign the print-mark-sensor signal to this input!