Cross cutter, Appendix – Lenze EVS93xx CrossCutter User Manual

Page 192

Advertising
background image

Cross Cutter

Appendix



Prepared Solution Servo PLC / ECSxA 1.1 EN

6-24

Outputs

Global variables

(Variable type: VAR_GLOBAL)

Name Data

type

Value/Meaning
Number of current motion profile

g_wMotionProfileAct

WORD

0 ... 47

Number of motion profile

"Profile zero crossing" status signal

g_bVertShaftPosZero BOOL

TRUE

Electrical shaft at profile zero crossing

g_dnVertShaftPosAct_p DINT

Actual angle of electrical shaft in [incr.]

g_nVertShaftVelocityAct_v INT

Current speed of electrical shaft
Sign of gradient of current profile
TRUE Negative

sign

g_bSignGradientProfileAct BOOL

FALSE Positive

sign

g_dnVertShaftLengthAct_p

DINT

Length of X axis of current profile in [incr.]
"Y axis speed limitation active" status signal

Please note that as long as limitation is active, the motor will not follow
the motion profile precisely!

g_bYAxisLimitBusy BOOL

TRUE

The speed of the Y axis is outside the

window defined using
g_nYAxisVelocityMin_v and
g_nYAxisVelocityMin_v.

g_dnYAxisPosAct_p DINT

Position of the Y axis

This variable maps the Y integrator of FB L_CamData.

The variable is used when connecting a cam group.

Status of FB L_CamData

0 No

errors

10

Warning: Profile not found.

g_nCamDataState INT

20

Warning: Excessive master value step
change

g_nCamVelocitySet_v INT

Setpoint speed of profile to be processed

g_dnYEndPos_p DINT

Current stroke at the end of a feed profile

g_CamAxis CAM_AXIS_

REF

Profile parameter

Data structure, the elements of which are written to the machine
parameters in the internal measuring system.

g_ProfileValues
R/W

CAM_
PROFILE_

REF

Data structure with the major points of the selected motion profile

Positions in [incr.]