Prepared Solution Servo PLC / ECSxA 1.1 EN

6-40

Possible settings:

Code

Default

Selection

Comment

C3361/

000

- -

{1[incr.]}

- Display code: Current master angle

C3365/

000

- -

{1[incr.]}

- Display code: Main integrator, current cam position

C3366/

000

- -

{1[incr.]}

- Display code: Auxiliary integrator, current tool position

C3367/

000

- -

{1[incr.]}

- Display code: Profile set position

C3369/

000

- -

{1[incr.]}

- Display code: Following error


Selection of application units
0 [mm]

C3501/

000

0 0

{1[m_units]}

1

1 [inch]
Display code: Status of state machine
100 "Init"

state

51 "LockToCamBusy"

state

50 "CamOperation"

state

40 "PositioningOperation"

state

30 "HomingOperation"

state

20 "ManualOperation"

state

10 "StandBy"

state

Switching over to other states is performed
from this initial state.

C3505/

000

- -

-

-

1 "Trouble"

state

C3620/

001

5.00 0.01…

{0.01[s]}

...129.99 Deceleration ramp for immediate stop

Assuming 4000 rpm

C3620/

002

5.00 0.01…

{0.01[s]}

...129.99 Acceleration ramp for positioning

Assuming 4000 rpm

C3620/

003

5.00 0.01…

{0.01[s]}

...129.99 Deceleration ramp for positioning

Assuming 4000 rpm

C3621/

001

200

0 ...

{1 rpm}

...15000 Speed for positioning in positive direction (CW)

C3621/

002

200

0 ...

{1 rpm}

...15000 Speed for positioning in negative direction (CCW)

C3622/

001

5.000 0.000...

{0.0001[s]}

...129.99

Deceleration ramp for immediate stop for manual jog

Assuming 4000 rpm

C3622/

002

5.000 0.000...

{0.0001[s]}

...129.99

Acceleration and deceleration ramp for normal operation;

Assuming 4000 rpm

C3622/

003

5.000 0.000...

{0.0001[s]}

...129.99

Acceleration and deceleration ramp for manual jog

Assuming 4000 rpm

C3623/

001

200 0

...

{1 rpm}

...15000

Speed for manual jog in positive direction (CW)

C3623/

002

200 0

...

{1 rpm}

...15000

Speed for manual jog in negative direction (CCW)

C3624

/001

5.00 0.01…

{0.01[s]}

...129.99 Deceleration ramp for immediate stop (function abort) for homing

Assuming 4000 rpm

C3624

/002

5.00 0.01…

{0.01[s]}

...129.99 Acceleration ramp for homing

Assuming 4000 rpm

C3624

/003

5.00 0.01…

{0.01[s]}

...129.99 Deceleration ramp for homing

Assuming 4000 rpm

C3625

/001

200

0 ...

{1 rpm}

...15000 Speed for homing in positive direction (CW)

C3625

/002

200

0 ...

{1 rpm}

...15000 Speed for homing in negative direction (CCW)

C3626
/000

0 0

{0.0001
[s_units]}

214000.0000 Entry indicating the position of the homing switch

C3627
/000

0 0

{0.0001
[s_units]}

214000.0000 Target position of tool following homing

C3628/

000

0.0000 0

{0.0001
[s_units]}

360.0000 Target position of positioning

Advertising