Rockwell Automation 294D ArmorStart LT Distributed Motor Controller DeviceNet Version - User Manual User Manual

Page 118

Advertising
background image

118

Rockwell Automation Publication 290D-UM001A-EN-P - June 2012

Chapter 4

Bulletin 290D/291D/294D Programmable Parameters

Zone4EPR

Expected Packet Rate for Zone 4
consuming connection

Parameter Number

133

Access Rule

SET

Data Type

UINT

Group

ZIP

Units

msec

Minimum Value

0

Maximum Value

65535

Default Value

75

Zone1Control

Enables/Disables options for Zone 1
control

Parameter Number

134

Access Rule

SET

Data Type

BYTE

Group

ZIP

Units

Minimum Value

0

Maximum Value

0x3F

Default Value

0x02

Bit

Function

7

6

5

4

3

2

1

0

— — — — — — —

X

SecurityEnable

— — — — — —

X

COSCnxn

— — — — —

X

— —

PollCnxn

— — — —

X

— — —

StrobeCnxn

— — —

X

— — — —

MulticastPoll

— —

X

— — — — —

FragmentedIO

X

X

— — — — — —

Reserved

Zone2Control

Enables/Disables options for Zone 2
control

Parameter Number

135

Access Rule

SET

Data Type

BYTE

Group

ZIP

Units

Minimum Value

0

Maximum Value

0x3F

Default Value

0x02