Bulletin 290D/291D/294D Programmable Parameters

Chapter 4

Figure 36 - Skip Frequency Band

SkipFrequency

Sets the frequency at which the drive will
not operate.

Parameter Number

73

Related Parameters

74

Access Rule

GET/SET

Data Type

UINT

Group

Advanced Config.

Units

Hz

Minimum Value

0

Maximum Value

400 Hz

Default Value

0 Hz

SkipFrqBand

Determines the band width around
Parameter 73 (SkipFrequency). Parameter
74 (SkipFreqBand) is split applying 1/2
above and 1/2 below the actual skip
frequency. A setting of 0.0 disables
this parameter.

Parameter Number

74

Related Parameters

73

Access Rule

GET/SET

Data Type

UINT

Group

Advanced Config.

Units

x.x Hz

Minimum Value

0.0 Hz

Maximum Value

30.0 Hz

Default Value

0.0 Hz

Frequency

Time

Skip Frequency

Command
Frequency

Drive Output
Frequency

2x Skip
Frequency Band