CIP Information

Appendix B

Analog Input Point Object

CLASS CODE 0x000A (Implemented in Bulletin 294D units only)

The following class attributes will be supported for the Analog Input Point
Object:

Two instances of the Analog Input Point Object will be supported.
CommandFreq from Assembly 154 is placed in the value attribute when
it is consumed.

The following common services will be implemented for the Analog Input Point
Object:

Analog Output Point Object

CLASS CODE 0x000B (Implemented in Bulletin 294D units only)

The following class attributes will be supported for the Analog Output Point
Object:

One instance of the Analog Output Point object will supported. It will represent
the Frequency command. CommandFreq from Assembly 154 is placed in the
Value Attribute when it is consumed. The Value Attribute can then be
overwritten by DeviceLogix.

Attribute ID

Access Rule

Name

Data Type

Value

1

Get

Revision

UINT

2

2

Get

Max Instance

UINT

1

Attribute ID

Access Rule

Name

Data Type

Value

3

Get

Value

INT

Default = 0

8

Get

Value Data Type

USINT

0 = INT

Service Code

Implemented for:

Service Name

Class Instance

0x0E Yes

Yes

Get_Attribute_Single

0x10 No

Yes

Set_Attribute_Single

Attribute ID

Access Rule

Name

Data Type

Value

1

Get

Revision

UINT

2

2

Get

Max Instance

UINT

1

Attribute ID

Access Rule

Name

Data Type

Value

3

Get/Set

Value

INT

0 = Default

8

Get

Value Data Type

USINT

0 = INT

129

Get/Set

Input Binding

STRUCT:

USINT
Array of USINT

Size of Appendix I encoded path

Appendix I encoded path

NULL path means attribute 3 drives the output.

Otherwise, this is a path to a bit in the Bit Table.