Appendix B

CIP Information

The following common services will be implemented for the Identity Object:

Message Router

CLASS CODE 0x0002

No class or instance attributes will be supported. The message router object exists
only to route explicit messages to other objects.

DeviceNet Object

CLASS CODE 0x0003

The following class attributes will be supported for the DeviceNet Object:

A single instance (instance 1) of the DeviceNet Object will be supported. The
following instance attributes will be supported.

➊ Allocation_byte

Bit 0 Explicit messaging
Bit 1 Polled I/O
Bit 4 COS I/O
Bit 5 Cyclic I/O
Bit 6 Acknowledge Suppression

4

Non-volatile configuration bad

5

Major fault – either bit 10 or bit 11 is true (1)

6

At least one I/O connection in run mode

7

At least one I/O connection established, all in idle mode

Service Code

Implemented for:

Service Name

Class

Instance

0x01 No

Yes

Get_Attributes_All

0x05 No

Yes

Reset

0x0E Yes

Yes Get_Attributes_Single

0x010 No

Yes

Set_Attributes_Single

Value

Description

Attribute ID

Access Rule

Name

Data Type

Value

1

Get Revision

UINT

2

Attribute ID

Access Rule

Name

Data Type

Value

1

Get/Set

Node Address

USINT

0 - 63

2 Get/Set

Baud Rate

USINT

0 = 125K
1 = 250K
2 = 500K

5 Get

Allocation Info

Allocation Choice
Master Node Addr

Structure of:

BYTE
USINT

Allocation_byte➊
0 - 63 = address
255 = unallocated

6

Get

MAC ID Switch Change

BOOL

8

Get

MAC ID Switch Value

USINT

0 - 63