Optional hoa selector keypad, Keypad local control – Rockwell Automation 294D ArmorStart LT Distributed Motor Controller DeviceNet Version - User Manual User Manual

Page 34

Advertising
background image

34

Rockwell Automation Publication 290D-UM001A-EN-P - June 2012

Chapter 1

Product Overview

Optional HOA Selector
Keypad

Keypad Local Control

The HOA Selector Keypad allows for local start/stop/jog control in forward/
reverse motor direction. If two buttons are pressed simultaneously, this action is
ignored by the device unless one of the buttons is the Off button. If the Off
button is pressed at any time, the unit will go to the off state. When local Hand
mode is entered, speed reference is switched to Internal Frequency. When in
“Auto” mode the unit the speed reference is switched to the mode specified in
parameter 33 “SpeedReference”.

Optional HOA Keypad
Configuration
(Bulletin 290D/291D only)

The ArmorStart LT offers optional factory-installed Hand/Off/Auto (HOA)
configurations: Standard (Bulletin 290D) and Forward/Reverse (Bulletin
291D).

Figure 8 - Bulletin 290D Standard HOA

Figure 9 - Bulletin 291D Forward/Reverse HOA

E

HAND

The Hand key will initiate starter operation

AUTO

The Auto key allows for Start/Stop control via the

communications network

OFF

If the starter is running, pressing the OFF key will cause the

starter to stop.

DIR Arrow The Dir arrow selects the direction of the motor, either forward

or reverse.

JOG

When pressed, JOG will be initiated if no other control devices

are sending a stop command. Releasing the key will cause the

drive to stop, using selected stop mode.