Rockwell Automation Publication 290D-UM001A-EN-P - June 2012

31

Product Overview

Chapter 1

Fault Diagnostics

Fault diagnostics capabilities built in the ArmorStart LT Distributed Motor
Controller are designed to help you pinpoint a problem for easy troubleshooting
and quick re-starting.

Protection Faults

Protection faults will be generated when potentially dangerous or damaging
conditions are detected. Protection faults are also known as “trips” or “faults”.
These faults will be reported in multiple formats, including:

Bit enumeration in the TripStatus parameter 16 in DeviceLogix

In the ArmorStart LT web server for ArmorStart EtherNet/IP version

As a sequence of LED flashes on the ECM

Table 5 - Protection Faults

➊ Cannot be disabled.

LED Flash

Bit Enumeration

290D/291D Trip Status Bits

294D Trip Status Bits

1

0

OverloadTrip ➊

OverloadTrip ➊

2

1

PhaseLossTrip

PhaseLShortTrip

3

2

UnderPowerTrip ➊

UnderPowerTrip ➊

4

3

SensorShortTrip ➊

SensorShortTrip ➊

5

4

PhaseImbalTrip

OverCurrentTrip

6

5

NonVolMemoryTrip ➊

NonVolMemoryTrip ➊

7

6

reserved

ParamSyncTrip ➊

8

7

JamTrip

DCBusOrDiscnnct ➊

9

8

StallTrip

StallTrip ➊

10

9

UnderloadTrip

OverTemperature ➊

11

10

reserved

GroundFault ➊

12

11

reserved

RestartRetries

13

12

reserved

DriveHdwFault ➊

14

13

OutputShortTrip ➊

OutputShortTrip ➊

15

14

UserDefinedTrip

UserDefinedTrip

16

15

HardwareFltTrip ➊

HardwareFltTrip ➊