Configuring System Information

227

Security Level — The security level attached to notifications. The possible field values are:
NoAu NoPriv — The packet is neither authenticated nor encrypted.

Auth NoPriv — The packet is authenticated.

Auth Priv — The packet is both authenticated and encrypted.

UDP Port (1

65535) — UDP port used to send notifications. The default is 162.

Filter Name — Check this check box to apply a user-defined SNMP filter (selected from the drop-

down menu) to notifications.

Timeout (1

300) — Amount of time (seconds) the device waits before resending informs. The default

is 15 seconds.

Retries (1

255) — Maximum number of times the device resends an inform request. The default is 3.

Adding a New Notification Recipient

1. Open the Notification Recipients page.
2. Click Add.

The Notification Recipients page displays:

Figure 6-107. Add Notification Recipient

3. Define the relevant fields.