240

Configuring System Information

• Plugged-in Model Identifier — A 16-byte character string to identify the plugged-in model of the

selected unit.

• Switch Status — Displays the status of the selected unit. The possible values are:

–

OK — The unit is in place and functioning.

–

Unsupported — The unit is in place, but can not function as a member of the stack.

–

Code Mismatch — The software of the switch does not match the master unit software.

–

Config Mismatch — The configuration of the switch does not match the master unit

configuration.

–

Not Present — The selected unit is not present.

• Switch Description — 80-byte data field used to identify the device.

Expected Code Type — Displays the expected code identifier.

• Detected Code Version — Running code version release number and version number.
•

Detected Code in Flash — Release number and version number of the code detected in flash.

•

Up Time — Displays how long the unit has been running since its last reset.

• Remove Switch — Select this option to remove switch from the stack.

Stack Summary

Use the Stack Summary page to view a summary of switches participating in the stack.
To display the Stack Summary page, click System > Stacking > Stack Summary in the tree view.

Figure 6-116. Stack Summary

The Stacking Summary page contains the following fields:

• Switch ID — ID of the unit. The maximum number of units allowed in the stack is 8.
•

Management Status — This field indicates whether the switch is currently operating as the

management switch, the standby switch, or a stack member.

• Standby Status — This field identifies the switch that is configured as the Standby Unit. Possible

values are: