1 logging in through an oap board, Oap board overview, Logging in to the operating system of an oap board – H3C Technologies H3C WX6000 Series Access Controllers User Manual

Page 29: Redirecting to an oap board from the device, Logging in through an oap board

Advertising
background image

1-1

1

Logging In Through an OAP Board

When logging in through an OAP board, go to these sections for information you are interested in:

z

OAP Board Overview

z

Logging In to the Operating System of an OAP Board

z

Resetting the System of an OAP Board

OAP Board Overview

As an open software and hardware system, Open Application Architecture (OAA) of Hangzhou H3C
Technologies Co., Ltd. (referred to as H3C herein after) provides a set of complete standard software
and hardware interfaces based on H3C devices. The third party vendors can develop products with
special functions. These products can be compatible with H3C devices as long as they conform to the
OAA interface standards. Therefore the functions of single network products can be expanded and the
users can get more benefits. Open Application Platform (OAP) is developed based on OAA. It can be an
independent network device, or a board used as an extended part of a device. An OAP board runs an
independent operating system. You can load software such as security and voice in the operating
system as needed. Meanwhile, after an OAP board is inserted into the expansion module slot of the
device, it interacts with the device on data, status information and control information through its internal
service interfaces

Logging In to the Operating System of an OAP Board

Logging in through the console port of the WX6103 main control board

You can log in to the operating system of the access controller interface board (an OAP board) through
the console port of the main control board of the WX6103 access controller. In this example, a PC acts
as a terminal.

1) Connect the serial port of the PC with the console port of the WX6103 main control board through a

console cable.

2) Run the terminal emulation program such as the HyperTerminal. Select the connection mode COM

and set the terminal parameters. Parameter requirements: set the bits per second to 9600, data
bits to 8, parity to none, stop bits to 1, and flow control to none.

3) Enter OAP board view from user view of the WX6103 main control board.

<H3C> oap connect slot 0

After the configuration, you can log in to the operating system of the WX6103 main control board, and
you can press Ctrl+K to return to the command line interface of the access controller.

Redirecting to an OAP board from the device

You can redirect to the operating system of an OAP board from the device through the following
operation. In this way, the terminal display interface will be switched from the command line interface on
the device to the operating interface of the operating system of the OAP board, and you can manage

Advertising