2-7

To do…

Use the command…

Remarks

Set the timeout time of the user
interface

idle-timeout

minutes

[ seconds ]

Optional
The default timeout time of a user
interface is 10 minutes.
With the timeout time being 10 minutes,
the connection to a user interface is
terminated if no operation is performed
in the user interface within 10 minutes.
You can use the idle-timeout 0
command to disable the timeout
function.

Note that if you configure to authenticate the users in the password mode, the command level available
to users logging in to the access controller switch interface board depends on both the

authentication-mode

password command and the user privilege level level command, as listed in

Table 2-5

.

Table 2-5

Determine the command level when users logging in to the access controller switch interface

board are authenticated in the password mode

Scenario

Authentication mode

User type

Command

Command level

The user privilege level level command
not executed

Level 0

Password
(authentication-mode
password

)

VTY users

The user privilege level level command
already executed

Determined by the
level

argument

Configuration Example

Network requirements

Assume that you are a level 3 Console user and want to perform the following configuration for Telnet
users logging in to VTY 0:

z

Authenticate users logging in to VTY 0 using the local password.

z

Set the local password to 123456 (in plain text).

z

Commands of level 2 are available to users logging in to VTY 0.

z

Telnet protocol is supported.

z

The screen can contain up to 30 lines.

z

The history command buffer can contain up to 20 commands.

z

The timeout time of VTY 0 is 6 minutes.

Network diagram

Figure 2-2

Network diagram for Telnet configuration