Error status for optional modules, Sva-01 error status  svb-01 error status – Yaskawa MP3200 Troubleshooting Manual User Manual

Page 146

Advertising
background image

7.5 System Register Configuration and Error Status

Error Status for Individual Products

7-20

Error Status for Optional Modules

This section shows the error status for the SVA-01, SVB-01, SVC-01, PO-01, and MPU-01 Modules.

SVA-01 Error Status

SVB-01 Error Status

SW00 + 0

Not used.

SW00 + 1

Not used.

SW00 + 2

Not used.

SW00 + 3

Not used.

SW00 + 4

Not used.

SW00 + 5

Not used.

SW00 + 6

Not used.

SW00 + 7

Not used.

F

8 7

0 (Bit number)

SW00 + 0

Error code (station error = 1)

Subslot (function) number (= 1)

F

2

1

0

(Bit number)

SW00 + 1

ST#15

···························

ST#2

ST#1

Not used.

F

E

D

SW00 + 2 Not used. ST#30 ST#29

···························

ST#17 ST#16

SW00 + 3

Not used.

SW00 + 4

Not used.

SW00 + 5

Not used.

SW00 + 6

Not used.

SW00 + 7

Not used.

Table 7.3 SVB-01 Error Status Details

Item

Code

Remarks

Error code

0

No error

1

Station error

ST#n

0

Communications normal

1

Communications error at station n

Advertising