7.5 System Register Configuration and Error Status

Module Information

7-37

T

roubleshooting System Errors

Function Module Status Details

CPU Unit/CPU Module Information

CPU-201, CPU-202, or CPU-301

Value

Text Displayed in MPE720

Module Configuration Definition

Status

0

None

There is no Module Definition and the Module is not mounted.

1

Empty

There is a Module Definition, but the Module is not mounted.

2

Operating (Driving)

The Module is operating normally.

3

Standby (Reserved for system.)

The Module is on standby.

4

Failure

An error was detected in the Module.

5

× Module name

The mounted Module does not match the definition.

6

Waiting for initialization

The Module is mounted, but there is no Detailed Function Module
Definition.

7

Driving Stop

Local I/O is stopped.

8 to

Reserved for system.

Name

Register

Addresses

Remarks

CPU Unit Information

SW00800

CPU Unit ID/CPU Module ID

SW00801

Hardware version (BCD)

SW00802

Software version (BCD)

SW00803

Number of sub-slots (hex)

SW00804

Function Module 1 ID (hex)

SW00805

Function Module 1 Status

SW00806

Function Module 2 ID (hex)

SW00807

Function Module 2 Status

SW00808

Function Module 3 ID (hex)

SW00809

Function Module 3 Status

SW00810

Function Module 4 ID (hex)

SW00811

Function Module 4 Status

SW00812

Function Module 5 ID (hex)

SW00813

Function Module 5 Status

SW00814

Function Module 6 ID (hex)

SW00815

Function Module 6 Status

Continued on next page.