Yaskawa MP3200 Troubleshooting Manual User Manual

Page 93

Advertising
background image

5.2 Troubleshooting Message Communications

Message Communications Errors

5-18

4.

Check the connection parameter settings.

Note: If message functions are used with the Enable Option selected, communications may not be performed

properly.

Table 5.1 Connection Parameter Check Items

Item

What to Check

Remarks

Local Port

Set the port number to which the remote station is
to send data.

Node IP Address

Set the IP address of the remote station.

Set 000.000.000.000 to use the unpas-
sive open mode.

Node Port

Set the port number from which the remote station
sends data.

To change the port number of the
remote station dynamically, use the
unpassive open mode. To use the
unpassive open mode, set 0000.

Connect Type

Set the connection type of the remote station.

Protocol Type

Set the protocol type that is supported by the remote
station.

Code

Set the code type of the remote station.

Unpassive Open Mode
To use unpassive open mode, set the connection parameters as follows:
• Set the IP address of the remote station (Node IP Address) to 000.000.000.000.
• Set the port number of the remote station (Node Port) to 0.
In unpassive open mode, the 218IFD connects to any station that attempts to access the rele-
vant connection number. If more than one station attempts access, the connection will be
established with the station that sent the connection request first.
When a connection is established in unpassive open mode, a connection request from another
station will break the current connection and establish a connection with the station that sent
the connection request later.

Using the 218IFD
Click the Detail Setting Button to display the Automatically Reception Dialog Box.
Select the Disable Option to use message functions.

Connection parameter settings

Information

Example

Advertising