7.5 System Register Configuration and Error Status

Error Status for Individual Products

7-22

MPU-01 Error Status

Error Status for Communications Modules

This section shows the error status for the 11 models of Communications Modules.

215AIF-01 Error Status

(MPUIF)

F

8 7

0 (Bit number)

SW00 + 0

Not used.

Subslot (function) number (= 1)

SW00 + 1

Not used.

SW00 + 2

Not used.

SW00 + 3

Not used.

SW00 + 4

Not used.

SW00 + 5

Not used.

SW00 + 6

Not used.

SW00 + 7

Not used.

(MPLINK/CP-215)

F

8 7

0 (Bit number)

SW00 + 0

Error code (station error = 1)

Subslot (function) number (= 2)

F

0

(Bit number)

SW00 + 1 ST#16

···························

ST#1

SW00 + 2 ST#32

···························

ST#17

SW00 + 3 ST#48

···························

ST#33

SW00 + 4 ST#64

···························

ST#49

SW00 + 5

Not used.

SW00 + 6

Not used.

SW00 + 7

Not used.

Table 7.5 MPLINK/CP-215 Error Status Details

Item

Code

Remarks

Error code

0

No error

1

Station error

ST#n

0

Communications normal

1

Communications error at station n