Yaskawa MP3200 Troubleshooting Manual User Manual

Page 156

Advertising
background image

7.5 System Register Configuration and Error Status

Error Status for Individual Products

7-30

LIO-04/LIO-05 Error Status

LIO-06 Error Status

(LIO32)

F

8 7

0 (Bit number)

SW00 + 0

Error code (I/O error = 2)

Subslot (function) number (= 1)

SW00 + 1

Not used.

SW00 + 2

Not used.

SW00 + 3

Not used.

SW00 + 4

Not used.

SW00 + 5

Not used.

SW00 + 6

Not used.

SW00 + 7

Not used.

Table 7.14 LIO-04/LIO-05 Error Status Details

Item

Code

Remarks

Error code

0

No error

2

I/O Error
Cause of Error
• Fuse error

(MIXIO)

F

8 7

0 (Bit number)

SW00 + 0

Error code (I/O error = 2)

Subslot (function) number (= 1)

3

2

1

0

(Bit number)

SW00 + 1

Not used.

ADJO ADJI FUSE FLT

(CNTR-A)

SW00 + 2

Error code (I/O error = 2)

Subslot (function) number (= 2)

2

1

0

(Bit number)

SW00 + 3

Not used.

PB

PA FLT

SW00 + 4

Not used.

SW00 + 5

Not used.

SW00 + 6

Not used.

SW00 + 7

Not used.