T

roubleshooting System Errors

260IF-01 Error Status

261IF-01 Error Status

(260IF)

F

8 7

0 (Bit number)

SW00 + 0

Error code (station error = 1)

Subslot (function) number (= 2)

F

0

(Bit number)

SW00 + 1 ST#15

···························

ST#0

SW00 + 2 ST#31

···························

ST#16

SW00 + 3 ST#47

···························

ST#32

SW00 + 4 ST#63

···························

ST#48

SW00 + 5

Not used.

SW00 + 6

Not used.

SW00 + 7

Not used.

Table 7.7 260IF-01 Error Status Details

Item

Code

Remarks

Error code

0

No error

1

Station error

ST#n

0

Communications normal

1

Communications error at station n