7.5 System Register Configuration and Error Status

Data Logging Execution Status

7-75

T

roubleshooting System Errors

Data Logging Execution Status

The data in these registers give the execution status of data logging.

Name

Register Addresses

Remarks

Data Logging Definition Existence SW24000

SB240000

0: Logging 1 definition does not exist,
1: Logging 1 definition exists

SB240001

0: Logging 2 definition does not exist,
1: Logging 2 definition exists

Data Logging Execution Status

SW24001

SB240010

0: Logging 1 is in progress,
1: Logging 1 is stopped

SB240011

0: Logging 2 is in progress,
1: Logging 2 is stopped

SB240012

0: Logging 3 is in progress,
1: Logging 3 is stopped

SB240013

0: Logging 4 is in progress,
1: Logging 4 is stopped

SB240014 to
SB240017

Reserved for system.

SB240018

0: Logging 1 is not waiting for trigger condition,
1: Logging 1 is waiting for trigger condition

SB240019

0: Logging 2 is not waiting for trigger condition,
1: Logging 2 is waiting for trigger condition

SB24001A

0: Logging 3 is not waiting for trigger condition,
1: Logging 3 is waiting for trigger condition

SB24001B

0: Logging 4 is not waiting for trigger condition,
1: Logging 4 is waiting for trigger condition

SB24001C
to SB24001F

Reserved for system.

Data Logging
Execution Sta-
tus Details

Logging 1

SL24002

File update counter

SQ24004

Latest record number

SW24008

Overrun counter

SW24009

Error code
0000 hex: No error,
0001 hex: No USB memory device
(at start of logging),
0002 hex: No USB memory device
(while logging is in progress),
0003 hex: Directory creation error,
0004 hex: File creation error,
0005 hex: File write error

SW24010 to SW24011

Reserved for system.

SW24012 to SW24043

Latest folder name

SW24044 to SW24065

Latest file name (includes extension such as
.csv)

Logging 2

SW24066 to SW24129

Same as Logging 1.

Logging 3

SW24130 to SW24193

Same as Logging 1.

Logging 4

SW24194 to SW24257

Same as Logging 1.

Reserved for system.

SW24258 to SW24321