5.2 Troubleshooting Message Communications

5-11

T

roubleshooting Programming and Debugging

No

Yes

No

Yes

No

Yes

A1

A2

B1

B2

From the

previous page

Is “---” (no display)

displayed in the

Transmis-

sion Status Box?

Is

IDLE displayed in

the

Transmission

Status Box?

Set the connection
parameters on the
Transmission Parameters
Tab Page of the Module’s
Detail Definition Dialog Box.

Save the data to flash
memory and then turn
the power supply OFF
and ON again.

Check the

Connection

Type Box in the Module’s
Detail Definition Dialog Box.

Is

TCP displayed in the

Connection Type Box?

(When using the
TCP protocol)

To the next page

(When using the
UDP protocol)

Check the following.
• Does the remote device exist and

is the power to the remote device
turned ON?

• Was the data saved to flash

memory and the power supply
turned OFF and ON again after
setting the parameters?

Perform the following operations.
• Create a message function.
• Execute the message function.
• Set the input items and

parameters correctly for the
message function.

Checking the Connection
Parameters (page 5-17)

Checking Message Functions
(MSG-SNDE and MSG-RCVE)
(page 5-20)