Electrical specifications – Nortel Networks 1000 User Manual

Page 123

Advertising
background image

Electrical specifications

123

Table 49
OPS analog line card - cable loop resistance and loss

Cable loop loss (dB)

(non-loaded at 1kHz)

Cable loop resistance (ohms)

Cable length

26 AWG

24 AWG

22 AWG

26 AWG

24 AWG

22 AWG

847 m (2800 ft)

1.5

1.2

0.9

231.4

144.2

90

1411 m (4600
ft)

2.5

2

1.6

385.6

240.3

150

1694 m (5600
ft)

3

2.4

1.9

462.8

288.3

180

2541 m (8300
ft)

4.5

3.7

2.8

694.2

432.5

270

8469 m (27800
ft)

15

12.2

9.4

2313.9

1441.7

900

The loss plan for the NT1R20 OPS Analog Line Card determines
port-to-port loss for connections between an OPS analog line card unit
(port) and other ports.

The transmission properties of each line unit are characterized by the OPS
or ONS class-of-service assigned in the analog 500/2500-type telephone
administration program LD 10.

The loss plan for the OPS analog line card determines port-to-port loss
for connections between an OPS analog line card unit (port) and other
Meridian 1 PE or IPE ports.

The transmission properties of each line unit are characterized by the
OPS or ONS class-of-service assigned in the Single-line Telephone
Administration program (LD10).

Electrical specifications

This section lists the electrical characteristics of the NT1R20 OPS analog
line card.

The signaling and control portion of the card provides circuits that
establish, supervise, and take down call connections. These circuits work
with the system CPU to operate the line interface circuits during calls. The
circuits receive outgoing call signaling messages from the CPU and return
incoming call status information over the DS-30X network loop.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.

Advertising