Trunk unit functions – Nortel Networks 1000 User Manual

Page 649

Advertising
background image

Functional description

649

Near-end seizure and outpulsing with M lead

Ground detection with E lead

Voice transmission through Tip and Ring for transmit and receive

Four-wire E and M signaling type I and II, two-way dial repeating (ESN
and Non-ESN)

echo suppression for type I

Switchable seven dB and 16 dB for carrier interface for ESN
applications

Transmit and receive of voice through two separate paths

Type I signaling through E and M leads

Type II signaling

Near-end seizure with MA/MB leads

Far-end detection with EA/EB leads

Paging trunk loop OAID operation

Support access by low resistance path at the PA/PB lead.

All call zone paging is not supported.

Two to four-wire conversion of the transmission path

Trunk unit functions

The functions provided by each unit on the E and M Trunk card include
2-wire signaling, 4-wire signaling, and paging operation as follows:

2-wire, E and M Type I signaling (see

Figure 212 "E and M Type I

signaling" (page 650)

) with:

near-end seizure and outpulsing with M lead

ground detection with E lead

voice transmission through tip and ring for transmit and receive

4-wire, E and M Type I and II signaling (see

Figure 213 "E and M Type

II signaling" (page 650)

), 2-way dial repeating with:

echo suppression for Type I signaling

switchable 7 dB and 16 dB pads for carrier interface

voice transmission and reception through two separate paths

Type I signaling through E and M leads

Type II signaling with near-end seizure by SB/M leads and far-end
detection by E/SG lead

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.

Advertising