Trunk cards, Procedure 9, Procedure 10 – Nortel Networks 1000 User Manual

Page 75

Advertising
background image

Trunk cards

75

If ALL is specified, all enabled loops (except attendant console
loops) and all shelves on each loop are tested.

If only one loop is being tested and it is disabled, enter

ENLL

loop

to enable and test a network card associated with the

specified loop. (This command cannot enable network cards
disabled by LD 32.)

If the system response is other than OK, see Software
Input/Output Reference — Administration
(NN43001-611) to
analyze the messages.

3

End the session in LD 30:

****

--End--

Trunk cards

Use the following procedures to test a trunk card.

Procedure 9
Testing a trunk card using a maintenance telephone

Step

Action

1

Access the system from a maintenance telephone.

See "Communicating with the Meridian 1" in the Software
Input/Output Reference — Administration
(NN43001-611) for
details on accessing the system from a maintenance telephone.

2

Test the trunk unit:

LD 36
TRK l s c u

loop, shelf, card, and unit numbers

3

If the maintenance telephone is hooked up to a monitor and the
system response is other than OK, see Software Input/Output
Reference — Administration
(NN43001-611) to analyze the
messages.

--End--

Procedure 10
Testing a trunk card using a system terminal

Step

Action

1

Log into the system:

LOGI

(password)

2

Enter:

LD 36

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.