Cs 1000e, cs 1000m, and meridian 1disconnect, Electrical specifications, Power requirements – Nortel Networks 1000 User Manual

Page 905: Environmental specifications

Advertising
background image

Electrical specifications

905

CS 1000E, CS 1000M, and Meridian 1disconnect

The CS 1000E, CS 1000M, and Meridian 1disconnects the call by
removing the loop between the tip and ring leads and replacing the ringing
detector. Trunks configured for battery supervision send a release confirm
message to software.

Electrical specifications

Power requirements

Table 386 "NTCK16 circuit card power requirements" (page 905)

shows

the power requirements for the NTCK16AX and NTCK16BX generic
Central Office trunk cards.

Table 386
NTCK16 circuit card power requirements

Voltage

Idle Current

Active current

+15.0 V dc

(See

"1" (page 905)

)

170 ma

330 ma

-15.0 V dc

(See

"1" (page 905)

)

170 ma

249 ma

+8.5 V dc

(See

"2" (page 905)

)

101 ma

100 ma

+5.0 V dc

160 ma

322 ma

Note 1:

Analog circuitry is powered with +/-12 V generated from +/-15

V. The maximum current imbalance between the +/-15 V rails is 100
ma per circuit pack.

Note 2:

8.5V is regulated to give 5 V.

Environmental specifications

Table 387 "NTCK16 circuit card environmental specifications" (page
905)

lists the environmental specifications of the NTCK16AX and

NTCK16BX generic Central Office trunk cards.

Table 387
NTCK16 circuit card environmental specifications

Parameter

Specifications

Operating temperature

10 to 45 degrees C

Operating humidity

20 to 80% RH (non-condensing)

Storage temperature

–20 to +60 degrees C

Storage humidity

5 to 95% Relative Humidity

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.

Advertising