T1 connections – Nortel Networks 1000 User Manual

Page 204

Advertising
background image

204

NT5D11 and NT5D14 Lineside T1 Interface cards

Table 86
Lineside T1 card - NT5D13AA Connector pinouts

I/O Panel

Connector

Pin

Lead Designations

NT5D
13AA

Lineside

T1 I/O

Conn

ector

Pin

Lineside T1 cable
connector to external
equipment

1

T1 Tip Receive Data

11

26

T1 Ring Receive Data

3

2

T1 Tip Transmit Data

1

DB15 male to T1 (P2)
Lineside T1 card is CPE
transmit to network and
receive from network

27

T1 Ring Transmit Data

9

3

Alarm out common

1

DB9 male to external alarm
(P3)

28

Alarm out (normally open)

2

4

Alarm out (normally closed)

3

7

Towards MMI terminal
Receive Data

2

31

Towards MMI terminal
Transmit Data

3

DB9 male towards MMI
(P5)
Wired as DCE
Data is transmitted on pin 2
(RXD) and received on pin
3 (TXD)

33

Ground

5

8

Control 1

7

32

Control 2

9

33

Ground

5

8

Control 1

7

32

Control 2

9

DB9 female away from
MMI (P4)
Wired as DTE
Data is transmitted on pin 2
(TXD)and received on pin 3
(RXD)

30

Away from MMI terminal
Transmit Data

3

6

Away from MMI terminal
Receive Data

2

T1 connections

T1 signaling for all 24 channels is transmitted over P2 connector pins 1, 3,
9, and 11 as shown in

Table 86 "Lineside T1 card - NT5D13AA Connector

pinouts" (page 204)

. Plug the DB15 male connector labeled "P2" into the

T1 link. T1 transmit and receive pairs must be turned over between the
Lineside T1 card and CPE equipment that is hardwired without carrier

Nortel Communication Server 1000