NT8D41BA Quad Serial Data Interface Paddle Board

Table 289
NT8D41BA DTE/DCE/Fiber switch settings (cont’d.)

Port 1 — SW 3

Port 1 — SW 2

Mode

1

2

3

4

5

6

1

2

3

4

5

6

NT1P61 (Fiber)

on

on

on

on

on

off

on

on

on

off

on

off

Port 4 — SW 9

Port 4 — SW 8

DTE (terminal)

on

on

on

off

on

off

off

on

off

on

off

on

DCE (modem)

off

off

off

on

off

on

on

off

on

off

on

off

NT1P61 (Fiber)

on

on

on

on

on

off

on

on

on

off

on

off

Software service changes

Once the NT8D841BA QSDI paddle board has been installed in the
system, the system software needs to be configured to recognize it, using
the Configuration Record program LD 17. Instructions for running this
program are found in Software Input/Output Reference — Administration
(NN43001-611).

Some of the prompts that are commonly used when running the
Configuration Record program LD 17 are shown in

Table 290 "LD 17 -

Prompts to configure the NT8D841Ba paddle board." (page 728)

These

parameters must be set for each port if both ports are being used.

Table 290
LD 17 - Prompts to configure the NT8D841Ba paddle board.

Prompt

Response

Description

REQ:

CHG

Change configuration

TYPE:

ADAN

Configuration type

ADAN

NEW TTY x

NEW PRT x

Define a new system terminal (printer) port as device x, where
x = 0 to 15.

CTYPE

SDI4

Quad port card

DES

XQSDI

Quad density QSDI paddle board.

USER

xxx

Enter the user of port x. The values that can be entered
depend on the software being used. See the Software
Input/Output Reference — Administration
(NN43001-611) for
details.

XSM

(NO) YES

Port is used for the system monitor.