Equivalencies – Nortel Networks 1000 User Manual

Page 915

Advertising
background image

Applications

915

Therefore the following steps must be followed when the Generic XFCOT
is installed:

1.

Define Loss Switching mode. Respond to the prompts in LD 97 as

shown.

Table 393
LD 97 - Defining Loss Switching mode.

Prompt

Response

Description

REQ:

CHG

TYPE:

SYSP

IPE system parameters configuration

...

NATP

YES

Select North American transmission plan.

Note: The default to the NATP prompt is NO, and therefore this
prompt must always be checked during installation.

2.

Define Loss Switching Class Of Service. Respond to the prompts in

LD 14 as shown.

Table 394
LD 14 - Defining Loss Switching Class Of Service.

Prompt

Response

Description

REQ:

CHG

TYPE:

COT

XTRK

XCOT

SIGL

LOP

...

CLS

LOL

LOL= Long Line

Note: The XFCOT uses the CLS Long Line (LOL) and Short
Line (SHL) for Loss Switching purposes and that the card and
trunk type is different from the XUT.

Equivalencies

The following equivalencies do apply:

XFCOT COT SHL is equivalent with XUT COT TRC

XFCOT COT LOL is equivalent with XUT COT NTC.

The entries TRC and NTC are no longer allowed for the Generic XFCOT.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.