Power requirements – Nortel Networks 1000 User Manual

Page 436

Advertising
background image

436

NT8D02 and NTDK16 Digital Line cards

Table 172
NT8D02 Digital Line Card - line interface unit electrical characteristics

Characteristics

Description

Units per card

16 voice, 16 data

Line rate

512 kbps ± 100 ppm

Impedance

100 ohms

Loop limits

0 to 1067 m (3500 ft.) with 24 AWG

PVC cable (±15 V dc at 80 mA)

Maximum ac Signal loss

15.5 dB at 256 KHz

Maximum dc Loop resistance

210 ohms

Transmitter output voltage:

successive "1" bits

+1.5 ± 0.15 V and –1.5 ± 0.15 V

"0" bits

0 ± 50 mV

Power requirements

The digital line card needs +15V DC over each loop at a maximum current
of 80 mA. It requires +15V, -15V, and +5V from the backplane. The line
feed interface can supply power to one loop of varying length up to 1070 m
(3500 ft) using 24 AWG wire with a maximum allowable AC signal loss of
15.5 dB at 256 kHz, and a maximum DC loop resistance of 210 ohms; 26
AWG wire is limited to 745 m (2450 ft).

Table 173
Digital line card-power required

Voltage

Current (max.)

±5.0 V dc

150 mA

+15.0 V dc

1.6 Amp

–15.0 V dc

1.3 Amp

The digital line card needs +15V DC over each loop at a maximum current
of 80 mA. It requires +15V, -15V, and +5V from the backplane. The line
feed interface can supply power to one loop of varying length up to 1070 m
(3500 ft) using 24 AWG wire with a maximum allowable AC signal loss of
15.5 dB at 256 kHz, and a maximum DC loop resistance of 210 ohms; 26
AWG wire is limited to 745 m (2450 ft).

The digital line card provides +15 V dc over each loop at a maximum
current of 80 mA. It requires +15 V, -15 V, and +5 V from the backplane.
One NT8D06 Peripheral Equipment Power Supply ac or NT6D40
Peripheral Equipment Power Supply dc can supply power to a maximum of
16 digital line cards.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.