Elei additional functionality, Electrical specifications – Nortel Networks 1000 User Manual

Page 264

Advertising
background image

264

NT5D33 and NT5D34 Lineside E1 Interface cards

ELEI additional functionality

As mentioned earlier, ELEI cards are enhanced to allow CAS+
compliance, as shown in

Figure 57 "CAS+ compliance" (page 264)

. This

enhancement provides several additional benefits for systems with ELEI
cards installed.

Note:

MDECTS and ELEI (operating in enhanced mode) cannot be

configured on the same system.

Figure 57
CAS+ compliance

Key Benefits of using CAS+ signaling (ELEI mode) over traditional A/B bit
signaling (LEI mode) include:

1.

Calling Line ID Presentation (CLIP)
When an incoming call over the TDM/IP network or a CS
1000originated call is directed towards the CAS+ compliant system,
Calling Line ID can be provided over the CAS+ interface. This is
assuming that the incoming call has the CLID without any presentation
restrictions.

2.

Redirecting Line ID Presentation (RLIP)
When an incoming call over the TDM/IP network or a CS
1000originated call which has undergone redirections is directed
towards the CAS+ compliant system, Redirecting Line ID can be
provided over the CAS+ interface. This is assuming that the incoming
call has the Redirecting Line ID without any presentation restrictions.

3.

Message waiting indication (MWI)
Message waiting indication can be provided over the CAS+ interface.

Electrical specifications

Table 98 "LEI card - line interface unit electrical characteristics" (page
265)

provides a technical summary of the E1 line interface.

Table 99 "LEI

card - power required" (page 265)

lists the maximum power consumed

by the card.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008