NT8D09 Analog Message Waiting Line card

Table 193
Power requirements (cont’d.)

Voltage
(+/-)

Tolerance

Idle
current

Active
current

Max

–48.0 V dc

5.00 V dc

0 mA

10 mA
(Note 1)

320
mA

86.0 V ac

5.00 V ac

0 mA

10 mA
(Note 2)

160
mA

–150.0 V dc

3.00 V dc

0 mA

2 mA

32
mA

Note 1: Each active ringing relay requires 10 mA of battery voltage.

Note 2: Reflects the current for ringing a single station set (or DN telephone).
There may be as many as five ringers on each line.

Table 194 "Analog message waiting line card - power requirements" (page
470)

provides the power requirements for the analog message waiting line

card.

Table 194
Analog message waiting line card - power requirements

Voltage
(+/–)

Tolerance

Idle
current

Active
current

Maximum

+12.0 V dc

0.36 V dc

48 mA

0 mA

48 mA

+8.5 V dc

0.40 V dc

150 mA

8 mA

280 mA

–48.0 V dc

2.00 V dc

48 mA

40 mA*

688 mA

–48.0 V dc

5.00 V dc

0 mA

10 mA**

160 mA

86.0 V ac

5.00 V ac

0 mA

10 mA***

160 mA

–150.0 V dc

3.00 V dc

0 mA

2 mA

32 mA

* Current required for each line off-hook

** Each active ringing relay requires 10 mA of battery voltage

*** Reflects the current for ringing a single DN telephone. There may be as
many as five ringers on each line.

Table 195 "Power requirements" (page 471)

provides the power

requirements for the analog message waiting line card.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.

Advertising