Carrier shield grounding (switch sw4) – Nortel Networks 1000 User Manual

Page 882

Advertising
background image

882

NTBK50 2.0 Mb PRI card

NTBK50 enables the shield of the Tx and/or Rx pairs of the carrier to be
selectively grounded. Closing (down position) the on-board switch applies
FGND to the appropriate carrier cable shield. The switch settings are
shown in

Table 379 "Carrier Shield grounding switch settings" (page 882)

.

Carrier Shield grounding (Switch SW4)

Table 377 "Carrier Shield grounding switch settings" (page 882)

lists the

Carrier Shield ground switch settings.

Table 377
Carrier Shield grounding switch settings

Switch

Down (On)

Up (Off)

SW 4 – 1

Rx – FGND

Rx – OPEN

SW 4 – 2

Tx – FGND

Tx – OPEN

Note:

The usual method is to ground the outer conductor of the receive

coax signal.

Settings are shown in the Table below.

Table 378
Carrier shield grounding switch settings

Switch

Down (On)

Up (Off)

SW 4-1

Rx—FGND

Rx—OPEN

SW 4-2

Tx—FGND

Tx—OPEN

Note:

The usual method is to ground the outer conductor of the receive

coax signal.

Table 379 "Carrier Shield grounding switch settings" (page 882)

lists the

Carrier Shield ground switch settings.

Table 379
Carrier Shield grounding switch settings

Switch

Down (On)

Up (Off)

SW 4 – 1

Rx – FGND

Rx – OPEN

SW 4 – 2

Tx – FGND

Tx – OPEN

Note:

The usual method is to ground the outer conductor of the receive

coax signal.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard