Installation

395

A stable ambient operating temperature of approximately 22



C (72



F) is

recommended. The temperature differential in the room should not exceed
±3



C (±5



F).

The internal power supply in each module provides DC power for the
MSDL and other cards. Power consumption and heat dissipation for the
MSDL is listed in

Table 161 "MSDL power consumption" (page 395)

.

Table 161
MSDL power consumption

Voltage

(VAC)

Current

(Amps)

Power

(Watts)

Heat

(BTUs)

+5

3.20

16.00

55.36

+12

0.10

1.20

4.15

–12

0.10

1.20

4.15

Installation

Device number

Before installing MSDL cards, determine which of the devices in the
system are available. If all 16 devices are assigned, remove one or more
installed cards to replace them with MSDL cards.

Make sure that the device number assigned to the MSDL card is not used
by an installed card, even if one is not configured. Use the MSDL planning
form, at the end of this section, to assist in configuring MSDL cards.

MSDL interfaces

Before installing the cards, select the switch settings that apply to your
system, the interfaces, and card addresses.

Table 162 "MSDL interface switch settings" (page 395)

shows the switch

positions for the DCE and the DTE interface configurations on the MSDL
card.

Figure 103 "MSDL switch setting example" (page 396)

shows the

MSDL and the location of configuration switches on the MSDL. The switch
settings shown in this figure are an example of the different types of
interfaces available. Your system settings may differ.

Table 162
MSDL interface switch settings

DCE
switch

DTE
switch

Interface

Comment

OFF

OFF

RS-232

DTE/DCE is software
configured

OFF

ON

RS-422 DTE

All switches configured