NT5D33 and NT5D34 Lineside E1 Interface cards

Table 105
ELEI card - E1 Switch 2 (S2) dip switch settings

Characteristic

Selection

Switch

Position

Switch

Setting

Factory

Default

E1 framing

CRC-4 Disabled

CRC-4 Enabled

1

ON

OFF

ON

E1 coding

AMI

HDB3

2

ON

OFF

OFF

NOT USED

leave ON

3

ON

ON

NOT USED

leave ON

4

OFF

OFF

Mode

LEI Mode

ELEI Mode

5

OFF

ON

OFF

Line processing on E1 link
failure

On-hook

Off-hook

6

ON

OFF

OFF

Daisy-chaining to MMI

YES

NO

7

ON

OFF

OFF

MMI master or slave

Master

Slave

8

ON

OFF

ON

After the card has been installed, display the dip switch settings using
the MMI command Display Configuration (D C). See

“Man-Machine E1

maintenance interface software” (page 284)

for details on this and the rest

of the available MMI commands.

Installation

Because of the wiring in some of the system modules and cabinets, the
LEI only works in certain card slot pairs. These restrictions depend on
the type of module or cabinet. In all other modules or cabinets where the
conditions listed below do not exist, the LEI works in any two adjacent card
slots:

In the NTAK12 Small Remote IPE Expansion Cabinet only card slots
10-15 are available.

In the NT8D37 IPE module, if the 25-pair I/O connectors are partially
split between adjacent IPE card slots, the LEI works only in card slots
where Unit 0 of the motherboard card slot appear on the first pair of
the 25-pair I/O connector.