PC card interface

923

Use 100BaseT to connect to the LAN for voice distribution over a data
network.

Use 100BaseT cable if connected point-to-point (directly) to the Media
Gateway. The NTTK34AA crossover cable must be used. The Media
Gateways can be located up to 100 meters from the Call Server.

Use Media Conversion devices (third party converters) to convert
100BaseT to fiber for distances from 100 m to 40 km.

See

Figure 264 "Call Server connection to Media Gateway" (page 923)

.

Figure 264
Call Server connection to Media Gateway

For further information or installation instructions, refer to Communication
Server 1000M and Meridian 1 Large System Installation and Configuration
(NN43021-310).

PC card interface

The NTDK20 SSC card has a PC card interface through a socket located
on its faceplate. The PC card socket can accommodate a Software
Delivery card used for software upgrading and as backup media.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008