Table 103 "lei, Card - xpec, Address dip – Nortel Networks 1000 User Manual

Page 270: Switch settings, Switch s1, Positions 3-6)

Advertising
background image

270

NT5D33 and NT5D34 Lineside E1 Interface cards

Table 101
LEI card - Switch 1 dip switch settings (cont’d.)

Characteristic

Selection

Switch

Position

Switch

Setting

Factory

Default

Card type for ringer
allocation

XTI = 19

XMLC = 18

7
7

ON

OFF

OFF

E1 signaling

See

Table 102

"LEI card -

signaling-type dip

switch settings"

(page 270)

8

OFF

OFF

When dip switch #1, positions 2 and 8 are set to "Table," AB Bits are
configured by the user through the Set Mode MMI command (see

“Set

Mode” (page 294)

). Otherwise, the signaling scheme selected by dip

switch 1, positions 2 and 8 are used.

Table 102
LEI card - signaling-type dip switch settings

Switch #1

Characteristic

Selection

Position 2

Position 8

Loop start

OFF

OFF

Ground start

ON

OFF

Australian P2

OFF

ON

Signaling Type

Table

ON

ON

Table 103
LEI card - XPEC address dip switch settings (Switch S1, positions 3-6)

XPEC

Address

S1 Switch
Position 3

S1 Switch
Position 4

S1 Switch
Position 5

S1 Switch
Position 6

00

OFF

OFF

OFF

OFF

01

ON

OFF

OFF

OFF

02

OFF

ON

OFF

OFF

03

ON

ON

OFF

OFF

04

OFF

OFF

ON

OFF

05

ON

OFF

ON

OFF

06

OFF

ON

ON

OFF

07

ON

ON

ON

OFF

08

OFF

OFF

OFF

ON

09

ON

OFF

OFF

ON

10

OFF

ON

OFF

ON

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.