NT8D15 E and M Trunk card

Table 257
DX signaling - outgoing calls with originating party release on tandem connections (cont’d.)

Condition

Current in
signaling lead

State of trunk
detector

Dial CO/FX/WATS

Current flow
interrupted for each
pulse

High

Stop sender

No current flow

Low

Go sender (universal service provided by
far-end PBX if originating end is senderized)

Current flow

High

CO/FX/WATS offices ready for digits

Stored Office DN digits

Current flow
interrupted for each
pulse

High

Outpulsed

No current flow

Low

Far-end answers

No current flow

Low

Far-end on hook first

Current flow

High

Near-end on hook, network taken down, trunk
idled

No current flow

High

Near-end on hook first, network taken down

Current flow

Low

Far-end on hook, trunk idled

No current flow

High

Table 258
DX signaling - incoming calls with originating party release on tandem connections

Condition

Current in
signaling lead

State of trunk
detector

Idle

No current flow

High

Seizure
(CS 1000 can be arranged for IS, DD, or WS)

Current flow

Low

Near-end ready for digits

Dial CO/FX/WATS and office DN

Current flow
interrupted for each
pulse

Low-high-low for each
pulse

If a ground start*, the stored digits are sent out
on CO/FX/WATS trunk after ground detection. If
a loop start, the stored digits are outpulsed on
CO/FX/WATS trunk after 3 seconds.

If answer supervision is enabled, pseudo-answe
r supervision is sent approximately 13 seconds
after last dial pulse is received

No current flow

Low

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.