Acceptance tests

3

To test a trunk from a remote test center, seize a central office
(CO) monitor trunk:

CALL

or

CALL l s c u

Seize the automatic number identification (ANI) trunk:

TRK l s c

u

loop, shelf, card, and unit numbers

When you see the

DN?

prompt, enter the directory number (DN)

you want the system to dial.

If the system response is other than OK, see the Software
Input/Output Reference — Administration
(NN43001-611) to
analyze the messages.

4

End the session in LD 36:

****

5

Test an automatically identified outward dialing (AIOD) trunk
card:

LD 41
AIOD l s c

loop, shelf, and card numbers

If the system response is other than OK, see Software
Input/Output Reference — Administration
(NN43001-611) to
analyze the messages.

6

End the session in LD 41:

****

--End--

Tone and digit switch cards

Procedure 11
Testing tone and digit switch cards

Step

Action

Use this procedure to test a tone and digit switch (TDS) card or to test the TDS
function of an NT8D17 Conference/TDS card.

1

Log into the system:

LOGI

(password)

2

Obtain a list of terminal numbers (TNs) for disabled TDS cards:

LD 34
STAD

3

If the TDS loop to be tested is disabled, enable it.

For an NT8D17 Conference/TDS card, enter:

ENLX loop

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008