NT8D15 E and M Trunk card

Table 260
Electrical characteristics of trunk cards

Characteristic

DID Trunk

CO trunk

Nominal impedance

600 or 900 ohms, (selected by
software)

600 or 900 ohms, (selected by
software)

Signaling range

2450 ohms

1700 ohms

Signaling type

Loop

Ground or loop start

Far-end battery

-42 to -52.5 V

-42 to -52.5 V

Near-end battery

N/A

-42.75 to -52.5 V

Minimum loop current

N/A

20 mA

Ground potential difference

+ 10 V

+ 3 V

Low DC loop resistance during
outpulsing

N/A

300 ohms

High DC loop resistance

N/A

Ground start equal to or greater
than 30 kS. Loop start equal to
or greater than 5 MS

Line leakage

Equal to or greater than 30 kS
(Tip to Ring, Tip to GND, Ring
to GND).

Equal to or greater than 30 kS
(Tip to Ring, Tip to GND, Ring
to GND)

Effective loss

See pad table

See pad table

Table 261 "Electrical characteristics" (page 692)

lists the electrical

characteristics of the trunk interface on the E and M Trunk card.

Table 261
Electrical characteristics

Characteristic

4-wire trunk

2-wire trunk

Signaling range

Type I

150 ohms

Type II

300 ohms loop

Type I

150 ohms

Signaling type

Type I, Type II

Type I

Far-end battery

–42 to –52.5 V dc

–42 to –52.5 V dc

Near-end battery

–42.75 to –52.5 V dc

–42.75 to –52.5 V dc

Ground potential difference

±10 V dc

±10 V dc

Line leakage between E lead and
ground

ˇ

S20K

1

/

2

³20K

1

/

2

Effective loss

See pad table (

Table 281

"Pad switching algorithm"

(page 711)

)

See pad table (

Table 281

"Pad switching algorithm"

(page 711)

)

Terminating impedance

600 ohms

600 ohms

Balance impedance

N/A

600 ohms

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.