Table 254 "dx – Nortel Networks 1000 User Manual

Page 683

Advertising
background image

Operation

683

Table 253
DX signaling - outgoing calls with originating party release on tandem connections (cont’d.)

Condition

Current in
signaling lead

State of trunk
detector

Dial CO/FX/WATS

Current flow
interrupted for each
pulse

High

Stop sender

No current flow

Low

Go sender (universal service provided by
far-end PBX if originating end is senderized)

Current flow

High

CO/FX/WATS offices ready for digits

Stored Office DN digits

Current flow
interrupted for each
pulse

High

Outpulsed

No current flow

Low

Far end answers

No current flow

Low

Far end on hook first

Current flow

High

Near end on hook, network taken down, trunk
idled

No current flow

High

Near end on hook first, network taken down

Current flow

Low

Far end on hook, trunk idled

No current flow

High

Table 254
DX signaling - incoming calls with originating party release on tandem connections

Condition

Current in signaling
lead

State of trunk
detector

Idle

No current flow

High

Seizure
(Meridian 1 may be arranged for IS, DD, or WS)
(near-end ready for digits)

Current flow

Low

Dial CO/FX/WATS and office DN

Current flow
interrupted for each
pulse

Low-high-low for each
pulse

Stored digits outpulsed on CO/FX/WATS trunk
after ground detection if a ground start, but after
3 seconds if a loop start

If answer supervision: pseudo-answer
supervision is sent approximately 13 seconds
after last dial pulse received

No current flow

Low

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.

Advertising