NTAK79 2.0 Mb PRI card

Table 354
Digital pad values and offset allocations (cont’d.)

PAD SET 0

PAD SET 1

Offset

PAD

Offset

PAD

10

10.0 dB

10

–10.0 dB

11

11.0 dB

11

spare

12

12.0 dB

12

spare

13

13.0 dB

13

spare

14

14.0 dB

14

Idle Code

15

spare

15

Unassigned Code

Signaling interface

The signaling interface consists of the A07 DS-30X signaling controller.
This interface provides an 8 Kbps signaling link through the DS-30X
timeslot zero data bit zero. Messages are 3 bytes in length.

The Meridian 1 signaling interface consists of the A07 DS-30X signaling
controller. This interface provides an 8 Kbps signaling link via the DS-30X
timeslot zero data bit zero. Messages are 3 bytes in length.

The signaling interface consists of the A07 DS-30X signaling controller.
This interface provides an 8 Kbps signaling link through the DS-30X
timeslot zero data bit zero. Messages are 3 bytes in length.

Carrier interface

The E1 interface connection to the external digital carrier is provided by
the line interface chip. This chip provides accurate pulse shaping to meet
the CCITT pulse mask requirements. It provides clock recovery functions
on the receive side as well as tolerance to jitter and wander in the received
bit stream.

For the E1 interface, the connection to the external digital carrier is
provided by the line interface chip. This device provides accurate pulse
shaping to meet the CCITT pulse mask requirements. It provides clock
recovery functions on the receive side as well as tolerance to jitter and
wander in the received bit stream.

The E-1 interface connection to the external digital carrier is provided by
the line interface chip. This chip provides accurate pulse shaping to meet
the CCITT pulse mask requirements. It provides clock recovery functions
on the receive side as well as tolerance to jitter and wander in the received
bit stream.