Table 148 "clock controller options - description – Nortel Networks 1000 User Manual

Page 349

Advertising
background image

Architecture

349

Table 148
Clock Controller options - description

Clock
Option

Notes

Option 1

This option provides a single CPU system with 2 clock sources
derived from the 2 ports of the DDP2.

Connector Clk0 provides a clock source from Unit 0.

Connector Clk0 provides a clock source from Unit 1.

Refer to

Figure 96 "Clock Controller - Option 1" (page 350)

.

Option 2

This option provides a Dual CPU system with 2 references of a
clock source derived from port 0 of the DDP2.

Connector Clk0 provides a Ref 1 clock source from Unit 0.

Connector Clk1 provides a Ref 2 clock source from Unit 0.

Refer to

Figure 97 "Clock Controller - Option 2" (page 351)

.

Option 3

This option provides a Dual CPU system with 2 references of a
clock source derived from port 1 of the DDP2.

Connector Clk0 provides a Ref 1 clock source from Unit 1.

Connector Clk1 provides a Ref 2 clock source from Unit 1.

Refer to

Figure 98 "Clock Controller - Option 3" (page 352)

.

Option 4

This option provides a Dual CPU system with 2 references from
each clock source derived from the DDP2.

Connector Clk0 provides a Ref 1 clock source from Unit 0.

Connector Clk1 provides a Ref 2 clock source from Unit 0.

Connector Clk0 provides a Ref 1 clock source from Unit 1.

Connector Clk1 provides a Ref 2 clock source from Unit 1.

Refer to

Figure 99 "Clock Controller - Option 4" (page 353)

.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.

Advertising